Connecting a heated floor to the boiler

Connecting a heated floor to the boilerTo heat a house located outside the city, various heating systems are used; in recent years, a “warm” water floor has been increasingly installed. Owners of such houses would benefit from some knowledge regarding connecting this device to the boiler. This knowledge will be useful either when installing this heating system yourself or for supervising the workers who will make such a connection.

Features of connecting a heated floor to a boiler

peculiaritiesThe underfloor heating system provides comfortable microclimatic conditions in the house. After the heated floor has been laid, it will need to be connected to the boiler installed in the house. This connection is made through the collector. Installation of heated floors is carried out in rooms with high humidity.

IMPORTANT! IN THE OPINION OF SOME SPECIALISTS, THE OPTIMAL HEATING SYSTEM IS CONSIDERED A COMPLEX OF A DOUBLE-CIRCUIT BOILER AND A “WARM” FLOOR CONNECTED TO IT, WHICH THE BOILER IS IN A SUSPENDED STATE AND IS EQUIPPED WITH FORCED DRAFT.

The simultaneous operation of the boiler and underfloor heating can provide the home with the necessary amount of heat.Such a system will eliminate the use of other types of boilers, for example, electric.

collectorThe “warm” floor must be connected to the boiler, via collector. What it is? That's what they call it a device that is designed to uniformly distribute the heated working medium to consumers connected to the boiler and, due to the circulation of the working fluid, it returns through it for heating.

After choosing a collector, it needs to be connected to the boiler. To perform this operation, you must strictly follow the instructions in the operating instructions for both units.

Connection diagram of the underfloor heating manifold to the boiler

There may be several connection methods. This depends on the type of boiler and its location. However, in all cases certain conditions must be met. It is better to connect the heated floor to the boiler according to the existing circuit. For example, this one.

Connection diagram of the underfloor heating manifold to the boiler

Installation subtleties

The placement of this component of the heating network directly depends on the decision made by the homeowner. In principle, it can be installed anywhere, the main thing is that it does not disturb anyone and is inaccessible to children. But, one way or another, there are recommendations that will not be superfluous at all:

  • The cabinet for installing the collector device must be installed in a room where access to pipeline lines will be provided.installation of heated floors to the boiler
  • The side fittings of the manifold device are connected to the ends of the pipes. Direct and reverse supply of coolant will be carried out through them. It is advisable to install the necessary shut-off valves and temperature regulators.
  • To simplify the procedure, it makes sense to buy a ready-to-install manifold, which includes shut-off valves.These units will be mounted on the terminals of underfloor heating, heating radiators and other heat consumers. During operation of the heating network, the homeowner will have the opportunity to turn off certain circuits of the heating network, but at the same time, some of the circuits will continue to operate.
  • The ends of the pipes, shut-off valves and the manifold are connected using fittings. Quite often, the outlet pipes of a heated floor are connected to the collector using connecting units consisting of a ring equipped with a clamp, a bushing and a nut made of brass. There is a simpler connection method, which is based on the use of simple clamps that are equipped with locking valves.
  • The heat supply and return pipes are connected to the inlet of the coolant distribution device, and the underfloor heating pipes are connected to the outlets.

Connection elements

The complete set of the collector unit consists of:

  • shut-off valves;
  • mixing unit;
  • drain tap;
  • pump to ensure the movement of the working medium.

Connection elementsIn the process of connecting the collector and underfloor heating elements to the boiler, the shut-off devices can be replaced with a valve with an installed thermostat. The main advantage of such a device is its ability to change dimensions in accordance with the temperature regime. After passing through this device, the coolant will receive a certain intensity of movement.

Connection procedure

As already noted, the optimal heating system can be considered a set of equipment consisting of:

  • boiler;
  • warm floor;
  • collector;
  • necessary strapping.

The connection of the listed components must be carried out in a certain order:

This work is carried out in a certain sequence:

  1. Selection of connection location. As usual, before connecting heating equipment, it is necessary to prepare the room. That is, it must have a flat floor and be equipped with drainage to remove water that may enter the room as a result of a breakthrough. Of course, it should have lighting installed. The dimensions of the room must provide free access for personnel to service installed devices.Connection procedure
  2. Direct and return pipelines are connected to the collector. The return will receive cooled water and redirect it to heating. Through a direct pipeline, the coolant, heated to the specified parameters, will be sent to the heating network.
  3. The boiler pipe is connected to a valve; fittings are used for this purpose and then connected to the manifold.
  4. Taps and temperature regulators must be installed at the ends of the pipes. They are designed to regulate the movement of coolant along the circuits and, if necessary, for example, in the event of an emergency, disconnecting damaged lines.
  5. The last operation is testing the assembled system.

Expert advice on how to properly connect a heated floor to a heating system

how to properly connect a heated floor to a heating systemThere is no single document on the technology of assembling the collector unit and connecting the heated floor to the boiler. But the principle of operation is the same. Meanwhile, there are certain rules that make sense to follow when performing this work.

For example, the expansion tank should be installed above the circulation pump. The installation location of this pump is not so critical, but experience shows that it is advisable to install it at the highest point of the heating system.

We must not forget that to increase the insulation of connections, fluoroplastic tape or thread should be used.