Gas boiler "Termotekhnik": what power, operating instructions

The Termotechnik boiler is designed for heating private houses by burning natural gas. The device provides a coolant temperature of up to 90 degrees, which is sufficient for heating and domestic use. The instructions for the Termotechnik gas boiler, as well as its characteristics and design, are described in this article.

Device and technical characteristics

The boiler is made in a metal body, which has a firebox and a heat exchanger. The latter contains several turbulators that ensure effective heat exchange between the burned gas and water. The main elements of the device are:

  • flue;
  • automation and gas valve (in case of emergency shutdown);
  • pipes for supplying and discharging water;
  • connecting pipes;
  • cups with thermal cylinder;
  • burners (pilot, main);
  • sensor that detects draft (thermostat).

Gas boiler thermotechnician instructionsa gas boiler

The operating instructions for the Termotechnik gas boiler contain a description of the main technical characteristics of the device:

  • gas pressure up to 1.27 kPa;
  • coolant type: water;
  • outlet water temperature up to 90 degrees;
  • optimal water temperature 60-80 degrees;
  • maximum pressure in the system 0.6 MPa;
  • optimal pressure 0.1 MPa;
  • minimum temperature of combustion products 110 degrees;
  • power from 1 to 20 MW (depending on modification);
  • water volume 14-30 l (depending on modification);
  • weight 37-77 kg (depending on modification);
  • water consumption to ensure a temperature of 90 degrees from 200 to 600 l/h (depending on modification).

User manual

The boiler can only be installed and connected by specialists who have the appropriate license. The premises must meet the minimum requirements:

  • height from 2.5 m;
  • doorway from 80 cm;
  • the presence of a window with an area of ​​at least 0.3 m2 for every 10 square meters of area;
  • the presence of a gas analyzer to prevent possible leaks;
  • installation in a basement with direct access to the street (not through the house) is possible.

Instructions for the gas boiler Termotechnik

The following rules for operating the device are also provided:

  1. Only water can be used. When connected in the winter season, it is preheated to at least 60 degrees, and continuous current is provided using a circulation pump.
  2. The maximum temperature of the coolant should be 90 degrees (constant monitoring using a sensor or thermometer is required).
  3. The heating circuit must be filled with water.
  4. The chimney must be cleaned and have normal draft.
  5. After shutdown, all gas valves are closed.
  6. During normal operation, you should not smell gas in the house - otherwise you need to turn off the fuel supply and find out the cause of the leak.

If headaches, dizziness, or ringing in the ears occur, you must immediately turn off the unit and ventilate the room. It is recommended to take all victims out into clean air and not let them fall asleep. In case of severe poisoning, they must call an ambulance, and before it arrives, they try to keep the person conscious; if necessary, they give him a cotton swab with ammonia to sniff.

Comments and feedback: