Water cooler device

For a detailed analysis of some aspects, you need to know what a cooler is. At a minimum, this is a device with which people can provide themselves with both cold and hot drinking water.

Water cooler device

Water cooler deviceThe design itself includes a body, its upper part is a bottle with liquid. It is equipped with two taps, they are intended for feeding, however, there are also models with three such products. As for the internal analysis, it is a system of various tubes and pipes. In addition to them, there are two reservoirs. One of them is responsible for cooling, and the other for heating. A valve is formed between them, it is thanks to it that the pressure is balanced, and therefore two liquids with different temperatures do not mix. It is worth not forgetting about the water inlet through which the supply is made.

Flow cooler operating diagram

The named device is made up of a four-stage filter and an ultraviolet lamp. This promotes the use of the water source as a piped water supply. Therefore, you don’t have to worry about possible contamination of bacterial particles, since they are completely eliminated inside the structure.In general, a deep cleaning is performed. And due to the fact that running water is used, we can safely talk about efficiency and the absence of restrictions on liquid consumption.

Flow cooler operating diagram

Scheme of operation of a cooler with flow cooling

Speaking about this system, one cannot fail to mention the following components:

  • Scheme of operation of a cooler with flow coolingA carbon prefilter that removes not only chlorine, but also various organic and chemical unnecessary substances.
  • Ultrafiltration filter. Thanks to it, characteristic components such as bacteria and viruses are removed. A reverse osmosis membrane also does a good job.
  • Sedimentary. Water is purified from elements whose size is at least 5 microns.
  • Compressor. It is necessary in order to establish a normalized pressure to convert the refrigerant into liquid (a function similar to a refrigerator).
  • A carbon post-filter removes unwanted odors and tastes from water that may remain after passing through the membrane.
  • Naturally, the device also includes taps with containers for dispensing cold and hot water.
  • To ensure optimal performance, a special pressure is required, which is what helps install a booster pump.

Principle of operation

After the main points of the design types have been sorted out, you can proceed to the general provisions of the operation process.

REFERENCE! The activity is carried out from an electrical network of 220 volts.

How is the water heated in the device?

To begin with, water in the required quantity fills a special compartment from the main compartment, which is intended for cooling and heating. When these containers lose a certain volume of liquid, they are refilled in new proportions.

IMPORTANT! This stage may differ in different production models. The cooler constantly maintains the temperature set by the user. This happens with the help of sensors. Therefore, you have the opportunity to get hot water without waiting.

This method is good because boiling is not carried out (maximum 98 degrees Celsius), which means that the beneficial properties and taste are not lost. Heating occurs due to a built-in heating element - a standard system similar to the operation of a kettle and similar inventions. The element itself can be either internal or external. This is determined relative to the reservoir.

How the water in the device is cooled

This aspect can be divided into two, namely electronic and compressor. The second of them is most similar to the process of operation of a refrigerator. To prevent the destruction of the ozone layer, a refrigerant is used, thereby ensuring environmental safety. In addition, here we can emphasize the speed and speed of temperature decrease.

The first system mentioned is equipped with two wafers, which, in fact, are semiconductors. One of them heats up during the supply of electric current, and the other cools down. Therefore, different degree measurements are obtained.

Exploitation

ATTENTION! It is strongly recommended not to connect the structure when there is no liquid inside. And also refrain from using it until three hours after installation. And do not forget about possible danger and electric shock. If problems or various malfunctions nevertheless arise, you should worry about safety and unplug the device from the outlet.

Use is carried out based on the instructions and certain requirements:

  • Types of water coolersInstall the unit on a smooth surface, the distance from it to the wall should be no less than 10–20 meters.
  • Protect the device from damp rooms and from sunlight.
  • Do not place near heating, heating or electrical devices.
  • Before use, wait two to three minutes to ensure that the reservoirs are completely filled with water.
  • The power line to which the cooler is connected must have a grounded contact.
  • The bottle must be in an upright position. First remove the hygienic film and then turn it upside down with the lid.
  • If the structure has not been used for a long time, it should be cleaned using cleaning products. This is necessary to avoid contamination.

Periodic monitoring of the fluid level is recommended. When it ends, you need to install a switch. At the moment when new products are in place, it is advisable to wait some time for the internal system to be completely filled. And only then start turning it on.

Comments and feedback:

Washing machines

Vacuum cleaners

Coffee makers